Pioneers in the industry, we offer multicore cable jz-500 grey 4 g 10 sq mm 10152 (18084694) 4 core 10 sq mm, no coded helukabel, multicore round cables jz-500 30g0.5 sq mm grey 10020 , no. coded ,30 core 0.5 sq mm helukabel, multicore round cables tronic (liyy) grey 4 x 0.34 sqmm grey part no. 18059 make helukabel, multicore round cables jz-500 grey 52 g 0.5 sqmm part no. 10169, no. coded 52core 0.5 sqmm helukabel, helukabel sihf 4g2.5 qmm rotbraun (23029) , 4 core 2.5 sq mm , silicone cable make helukabel and cable multicore jz-500 grey 18 g 0.75 sq. mm, (18084616) no.coded , 18 core, make helukabel from India.
₹ 850 / Meter Get Latest Price
| Number of Cores | 4 |
| Shape | Round |
| Conductor Size | 10 sqmm |
| Insulation Type | PVC |
| Voltage | 600 V |
| Insulation Material | FRLS PVC |
| Size | 10 sqmm |
| Cable Length | 500 m |
| Rated Voltage | 600 V |
| Cable Type | 4 Core |
| Conductor Material | Copper |
| Core Colour | Grey |
| Sheath Material | FR PVC |
| Application | Control, Panel Wiring, Industrial, Power, Instrumentation |
Minimum order quantity: 500 Meter
JZ-500 grey 4 G 10 mm²
VDE-registered |largely oil resistant }for selected torsion application|conditionally suitable for drag chains |versatile use in many industries, particularly in machine and plant construction
Item Details
|
JZ-500 grey 4 G 10 mm² AWG (approx.): 8 Outer Ø mm (approx.) ;16.4 Cu factor per km:384.0 Weight kg/km (approx.):701.0 Copper base in EUR / 100 kg:150 Metres per Packaging Unit:500, 1000 |
|
|
Cut-to-length service available:yes EAN / GTIN:4060892002700 Customs tariff number:85444995 Alternative cable designation:YSLY / YSLY-JZ, YY-cable |
|
|
|
Technical Data
PVC control and connection cable in alignment with DIN VDE 0285-525-2-51 / DIN EN 50525-2-51
|
Temperature range |
flexible -15°C to +80°C |
|
Nominal voltage |
AC U0/U 300/500 V |
|
Test voltage core/core |
4000 V |
|
Breakdown voltage |
8000 V |
|
Minimum bending radius |
flexible 7.5x Outer-Ø |
Details
Cable Structure
Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
Core insulation: PVC, compound type Z 7225
Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits
Protective conductor: starting with 3 cores,
· G = with protective conductor GN-YE, in the outer layer,
· x = without protective conductor (OZ)
Cores stranded in layers with optimal lay lengths
Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
Sheath colour: grey (RAL 7001)
Length marking: in metres
Properties
largely resistant to: oil,
for details, see "Technical Information"
conditionally torsional
conditionally suitable for drag chains
the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests
flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
certifications and approvals
EAC
VDE-Reg.-No. 7032, valid for temperature range up to +70°C
Notes
the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
please note "cleanroom qualification" in your order
Application
Used for flexible applications involving medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, in plant construction, air-conditioning technology, in smelters and steel mills. Select PVC compounds guarantee good flexibility, efficient and quick installation.
₹ 680 / Meter Get Latest Price
| Number of Cores | 30 |
| Shape | Round |
| Conductor Size | 0.5 sqmm |
| Insulation Type | PVC |
| Voltage | 600 V |
| Insulation Material | PVC |
| Size | 0.5 sq mm |
| Cable Length | 500 m |
| Cable Application | Control |
| Rated Voltage | 440 V |
| Cable Type | 30 |
| Conductor Material | Copper |
| Core Colour | Grey |
| Sheath Material | PVC |
| Application | Control |
| Conductor Type | Stranded |
Minimum order quantity: 100 Meter
TECHNICAL DATA
PVC control and connection cable in alignment with DIN VDE 0285-525-2-51 / DIN EN 50525-2-51 Temperature range flexible -15°C to +80°C fixed -40°C to +80°C
Nominal voltage AC U0/U 300/500 V
Test voltage core/core 4000 V
Breakdown voltage 8000 V
Minimum bending radius flexible 7.5x Outer-Ø fixed 4x Outer-Ø
PROPERTIES
• largely resistant to: oil, for details, see "Technical Information"
• conditionally torsional
• conditionally suitable for drag chains
• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
CABLE STRUCTURE
• Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
• Core insulation: PVC, compound type Z 7225
• Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits
• Protective conductor: starting with 3 cores, G = with protective conductor GN-YE, in the outer layer, x = without protective conductor (OZ)
• Cores stranded in layers with optimal lay lengths
• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
• Sheath colour: grey (RAL 7001)
• Length marking: in metres
TESTS
• flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332- 1-2 / IEC 60332-1-2
• certifications and approvals:
EAC
VDE-Reg.-No. 7032, valid for temperature range up to +70°C
APPLICATION
Used for flexible applications involving medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, in plant construction, air-conditioning technology, in smelters and steel mills. Select PVC compounds guarantee good flexibility, efficient and quick installation.
₹ 53 / Meter Get Latest Price
| Conductor Size | 0.34 sqmm |
| Insulation Material | FRLS PVC |
| Cable Length | 100 m |
| Rated Voltage | 300 V |
| Cable Type | 4 Core |
| Conductor Material | Copper |
| Core Colour | Grey |
| Sheath Material | FR PVC |
| Application | Control, Industrial, Instrumentation, Panel Wiring |
| Conductor Type | Stranded |
Minimum order quantity: 100 Meter
colour code DIN 47100, without colour repetition
TECHNICAL DATA
PVC data cable in alignment with DIN VDE 0812
Temperature range flexible -5°C to +80°C fixed -40°C to +80°C
Peak operating voltage 0.14 mm²: 350 V 0.25 - 1.5 mm²: 500 V (not for high power current installation purposes)
Test voltage core/core 0.14 - 0.25 mm²: 1200 V 0.34 - 1.5 mm²: 2000 V
Breakdown voltage 0.14 - 0.25 mm²: 2400 V 0.34 - 1.5 mm²: 4000 V
Mutual capacitance core/core at 800 Hz 0.14 - 0.25 mm²: approx. 100 pF/m 0.34 - 1.5 mm²: approx. 150 pF/m
Characteristic impedance 78 Ohm, (approx. value)
Inductance approx. 0.65 mH/km
Minimum bending radius flexible 7.5x Outer-Ø fixed 4x Outer-Ø
CABLE STRUCTURE
• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
• Wire structure:
0.14 mm²: approx. 18 x 0.1 mm
0.25 mm²: approx. 14 x 0.15 mm
0.34 mm²: 7 x 0.25 mm
• Core insulation: PVC acc. to DIN VDE 0207-363-3 / DIN EN 50363-3 (compound type TI2)
• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core
• x = without protective conductor
• Cores stranded in layers with optimal lay lengths
• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
• Sheath colour: grey (RAL 7001)
• Length marking: in metres
PROPERTIES
• largely resistant to: oil, for details, see "Technical Information"
• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
PROPERTIES
• largely resistant to: oil, for details, see "Technical Information"
• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
TESTS
• flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332- 1-2 / IEC 60332-1-2
• certifications and approvals:
EAC
APPLICATION
Suitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology
NOTES
• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
₹ 1200 / Meter Get Latest Price
| Conductor Size | 0.5 sqmm |
| Insulation Material | PVC |
| Cable Length | 500 m |
| Rated Voltage | 600 V |
| Cable Type | 52 Core |
| Conductor Material | Copper |
| Core Colour | Grey |
| Sheath Material | FR PVC |
| Application | Industrial, Panel Wiring, Control, Instrumentation |
| Conductor Type | Stranded |
Minimum order quantity: 500 Meter
₹ 440 / Meter Get Latest Price
| Conductor Size | 2.5 sqmm |
| Core Count | 4 Core |
| Cable Length | 100 m |
| Voltage Grade | 300/500 V |
| Conductor Material | Copper |
| Insulation Material | Silicone |
| Armour Type | Unarmoured |
| Application | Industrial, Instrumentation, Machine Tool, Control Panel |
Item Details
Part no. : 23029
Item description: SiHF redbrown 4 G 2.5 mm²
AWG (approx.):14
Outer Ø mm (approx.):10.6
Cu factor per :96.0
Weight kg/km (approx.) :188.0
Copper base in EUR / 100 kg:150
Metres per Packaging Unit :100, 500, 1000
Cut-to-length service available :yes
EAN / GTIN :4060892161056
Customs tariff number :85444995
Technical Data
|
Silicone control and connection cable in alignment with DIN VDE 0250-1, DIN VDE 0285-525-2-83 / DIN EN 50525-2-83 |
|
|
Temperature range |
flexible -25°C to +180°C |
|
Permissible operating temperature of the conductor |
+180°C |
|
Nominal voltage |
AC U0/U 300/500 V |
|
Test voltage core/core |
2000 V |
|
Breakdown voltage |
4000 V |
|
Minimum bending radius |
flexible 7.5x Outer-Ø |
₹ 342 / Meter Get Latest Price
| Number of Cores | 18 |
| Cable Type | 18 |
| Conductor Size | 0.75 sqmm |
| Shape | Round |
| Insulation Type | PVC |
| Conductor Material | Copper |
| Voltage | 500V |
| Insulation Material | FR PVC |
| Cable Length | 500 m |
| Size | 0.75 sq mm |
| Rated Voltage | 300V/500V |
| Cable Application | Control |
| Core Colour | Grey |
| Sheath Material | PVC |
| Application | Instrumentation, Control |
| Core Type | Multi Core |
Minimum order quantity: 100 Meter
₹ 65 / Meter Get Latest Price
| Cable Type | 2 Core |
| Conductor Size | 1 sqmm |
| Conductor Material | Copper |
| Insulation Material | PVC |
| Cable Length | Drum |
| Rated Voltage | 500V |
| Core Colour | Grey |
| Sheath Material | PVC |
| Application | Control |
Item Details
Part no. 10090
Item description OZ-500 grey 2 x 1.5 mm²
AWG (approx.) 16
Outer Ø mm (approx.) 6.4
Cu factor per km 29.0
Weight kg/km (approx.)70.0
Copper base in EUR / 100 kg 150
Metres per Packaging Unit 50, 100, 500, 1000
Cut-to-length service available yes
EAN / GTIN 4060892002083
Customs tariff number 85444995
Alternative cable designation YSLY / YSLY-JZ, YY-cable
Cable Structure
Properties
Tests
Notes
Application
₹ 45 / Meter Get Latest Price
| Cable Type | 2 Core |
| Conductor Size | 1 sqmm |
| Conductor Material | Copper |
| Insulation Material | FRLS PVC |
| Cable Length | 100 m |
| Rated Voltage | 600 V |
| Core Colour | Grey |
| Sheath Material | FRLS PVC |
| Application | Control |
| Conductor Type | Stranded |
Minimum order quantity: 100 Meter
OZ-500 grey 2 x 1 mm²Part no. 10060
VDE-registered
largely oil resistant
for selected torsion applications
conditionally suitable for drag chains
versatile use in many industries, particularly in machine and plant construction
Item Details
Item description:-OZ-500 grey 2 x 1 mm²
AWG (approx.):-18
Outer Ø mm (approx.):-5.6
Cu factor per km:-19.2
Weight kg/km (approx.):-60.0
Copper base in EUR / 100 kg:-150
Metres per Packaging Unit:-100, 500, 1000
Cut-to-length service available:-yes
EAN / GTIN:-4060892001789
Customs tariff number:-85444995
Alternative cable designation:-YSLY / YSLY-JZ, YY-cable
Technical Data
PVC control and connection cable in alignment with DIN VDE 0285-525-2-51 / DIN EN 50525-2-51
|
Temperature range |
flexible -15°C to +80°C |
|
Nominal voltage |
AC U0/U 300/500 V |
|
Test voltage core/core |
4000 V |
|
Breakdown voltage |
8000 V |
|
Minimum bending radius |
flexible 7.5x Outer-Ø |
Details
Cable Structure
Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
Core insulation: PVC, compound type Z 7225
Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits
Protective conductor: starting with 3 cores,
· G = with protective conductor GN-YE, in the outer layer,
· x = without protective conductor (OZ)
Cores stranded in layers with optimal lay lengths
Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
Sheath colour: grey (RAL 7001)
Length marking: in metres
Properties
largely resistant to: oil,
for details, see "Technical Information"
conditionally torsional
conditionally suitable for drag chains
the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests
flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
certifications and approvals
EAC
VDE-Reg.-No. 7032, valid for temperature range up to +70°C
Notes
the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
please note "cleanroom qualification" in your order
Application
Used for flexible applications involving medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, in plant construction, air-conditioning technology, in smelters and steel mills. Select PVC compounds guarantee good flexibility, efficient and quick installation.
₹ 225 / Meter Get Latest Price
| Cable Type | 12 Core |
| Conductor Size | 1 sqmm |
| Conductor Material | Copper |
| Insulation Material | FRLS PVC |
| Cable Length | 100 m |
| Rated Voltage | 600 V |
| Core Colour | Grey |
| Sheath Material | FRLS PVC |
| Application | Control |
| Conductor Type | Stranded |
Minimum order quantity: 100 Meter
OZ-500 grey 2 x 1 mm²Part no. 10060
VDE-registered
largely oil resistant
for selected torsion applications
conditionally suitable for drag chains
versatile use in many industries, particularly in machine and plant construction
Item Details
Item description:-JZ-500 grey 12 G 1 mm²
AWG (approx.):-18
Outer Ø mm (approx.):-10.9
Cu factor per km:-115.0
Weight kg/km (approx.):-230.0
Copper base in EUR / 100 kg:-150
Metres per Packaging Unit:-100, 500, 1000
Cut-to-length service available:-yes
EAN / GTIN:-4060892001901
Customs tariff number:-85444995
Alternative cable designation :-YSLY / YSLY-JZ, YY-cable
Technical Data
PVC control and connection cable in alignment with DIN VDE 0285-525-2-51 / DIN EN 50525-2-51
|
Temperature range |
flexible -15°C to +80°C |
|
Nominal voltage |
AC U0/U 300/500 V |
|
Test voltage core/core |
4000 V |
|
Breakdown voltage |
8000 V |
|
Minimum bending radius |
flexible 7.5x Outer-Ø |
Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
Core insulation: PVC, compound type Z 7225
Core identification acc. to DIN VDE 0293-334, black cores with consecutive labeling in white digits
Protective conductor: starting with 3 cores,
· G = with protective conductor GN-YE, in the outer layer,
· x = without protective conductor (OZ)
Cores stranded in layers with optimal lay lengths
Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
Sheath colour: grey (RAL 7001)
Length marking: in metres
Properties
largely resistant to: oil, for details, see "Technical Information", conditionally torsional
conditionally suitable for drag chains, the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests
flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
certifications and approvals
EAC,VDE-Reg.-No. 7032, valid for temperature range up to +70°C
Application
Used for flexible applications involving medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as a connection and control cable in machine tools, assembly lines and conveyor belts, production lines, in plant construction, air-conditioning technology, in smelters and steel mills. Select PVC compounds guarantee good flexibility, efficient and quick installation.
₹ 225 / Meter Get Latest Price
| Cable Type | Multi Core Copper |
| Core Count | 4 Core |
| Conductor Size | 1.5 |
| Shield Type | Braided Shield |
| Insulation Material | PVC |
| Application | Instrumentation |
| Voltage Rating | 600 V |
| Outer Sheath | PVC |
| Color Code | Color Coded |
| Cable Shape | Round |
Minimum order quantity: 100 Meter
TRONIC-CY (LiY-CY) grey 4 x 1.5 mm²Part no. 16502
· colour code DIN 47100, without colour repetition
· with drain wire
· EMC-preferred type
Item Details
Part no.:16502
Item description: TRONIC-CY (LiY-CY) grey 4 x 1.5 mm²
AWG (approx.): 16
Outer Ø mm (approx.): 8.7
Cu factor per km: 98.0
Weight kg/km (approx.): 126.0
Copper base in EUR / 100 kg: 150
Metres per Packaging Unit: 100, 500, 1000
Cut-to-length service available: yes
EAN / GTIN: 4060892087998
Customs tariff number: 85444995
Technical Data
|
PVC data cable in alignment with DIN VDE 0812 |
|
|
Temperature range |
flexible -5°C to +80°C |
|
Peak operating voltage |
0.14 mm²: 350 V |
|
Test voltage core/core |
0.14 - 0.25 mm²: 1200 V |
|
Test voltage core/screen |
0.14 - 0.25 mm²: 800 V |
|
Breakdown voltage |
0.14 - 0.25 mm²: 2400 V |
|
Mutual capacitance core/core |
at 800 Hz |
|
Mutual capacitance core/screen |
at 800 Hz |
|
Characteristic impedance |
78 Ohm, |
|
Inductance |
approx. 0.65 mH/km |
|
Coupling resistance |
at 30 MHz, approx. 250 Ohm/km |
|
Minimum bending radius |
flexible 10x Outer-Ø |
Cable Structure
Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
Strand construction:
0.14 mm²: approx. 18 x 0.1 mm
0.25 mm²: approx. 14 x 0.15 mm
0.34 mm²: 7 x 0.25 mm
Core insulation: PVC acc. to DIN VDE 0207-363-3 / DIN EN 50363-3 (compound type TI2)
Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core
x = without protective conductor
Cores stranded in layers with optimal lay lengths
Foil wrapping
Drain wire, tinned copper
Screen:1 core(s): helically wound tinned copper wires, approx. coverage 85 %
2 - 61 core(s): braided screen of tinned copper wires, approx. coverage 85 %
Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
Sheath colour: grey (RAL 7001)
Length marking: in metres
₹ 150 / Meter Get Latest Price
| Cable Type | 3 Core |
| Conductor Size | 0.23 sqmm |
| Conductor Material | Tinned Copper |
| Insulation Material | PVC |
| Cable Length | 500 m |
| Rated Voltage | 300 V |
| Core Colour | Black |
| Sheath Material | PVC |
| Application | Control |
| Conductor Type | Stranded |
Minimum order quantity: 500 Meter
₹ 79 / Meter Get Latest Price
| Cable Type | 3 Core |
| Conductor Size | 1.5 sqmm |
| Conductor Material | Copper |
| Insulation Material | PVC |
| Cable Length | 500 m |
| Rated Voltage | 440 V |
| Core Colour | Grey |
| Sheath Material | PVC |
| Application | Control |
| Conductor Type | Stranded |
Minimum order quantity: 500 Meter
₹ 33 / Meter Get Latest Price
| Cable Type | 4 Core |
| Conductor Size | 0.14 sqmm |
| Conductor Material | Copper |
| Insulation Material | FRLS PVC |
| Cable Length | 200 m |
| Rated Voltage | 300 V |
| Core Colour | Grey |
| Sheath Material | FR PVC |
| Application | Industrial, Instrumentation, Panel Wiring, Control |
| Conductor Type | Stranded |
Minimum order quantity: 200 Meter
₹ 27 / Meter Get Latest Price
| Cable Type | 2 Core |
| Conductor Size | 0.14 sqmm |
| Conductor Material | Copper |
| Insulation Material | FRLS PVC |
| Cable Length | 100 m |
| Rated Voltage | 300 V |
| Core Colour | Grey |
| Sheath Material | FR PVC |
| Application | Control, Instrumentation, Industrial, Panel Wiring |
| Conductor Type | Stranded |
Minimum order quantity: 300 Meter
TRONIC (LiYY) grey 2 x 0.14 mm² Part no. 18001
colour code DIN 47100, without colour repetition
TECHNICAL DATA
PVC data cable in alignment with DIN VDE 0812
Temperature range flexible -5°C to +80°C fixed -40°C to +80°C
Peak operating voltage 0.14 mm²: 350 V 0.25 - 1.5 mm²: 500 V (not for high power current installation purposes)
Test voltage core/core 0.14 - 0.25 mm²: 1200 V 0.34 - 1.5 mm²: 2000 V
Breakdown voltage 0.14 - 0.25 mm²: 2400 V 0.34 - 1.5 mm²: 4000 V
Mutual capacitance core/core at 800 Hz 0.14 - 0.25 mm²: approx. 100 pF/m 0.34 - 1.5 mm²: approx. 150 pF/m
Characteristic impedance 78 Ohm, (approx. value)
Inductance approx. 0.65 mH/km
Minimum bending radius flexible 7.5x Outer-Ø fixed 4x Outer-Ø
CABLE STRUCTURE
• Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
• Wire structure:
0.14 mm²: approx. 18 x 0.1 mm
0.25 mm²: approx. 14 x 0.15 mm
0.34 mm²: 7 x 0.25 mm
• Core insulation: PVC acc. to DIN VDE 0207-363-3 / DIN EN 50363-3 (compound type TI2)
• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core
• x = without protective conductor
• Cores stranded in layers with optimal lay lengths
• Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
• Sheath colour: grey (RAL 7001)
• Length marking: in metres
PROPERTIES
• largely resistant to: oil, for details, see "Technical Information"
• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
PROPERTIES
• largely resistant to: oil, for details, see "Technical Information"
• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
TESTS
• flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332- 1-2 / IEC 60332-1-2
• certifications and approvals:
EAC
APPLICATION
Suitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. For use where design or constructional measures in the outer diameter require the smallest possible control and signal cables; machine, tool and plant construction, as well as in electronic engineering. Also used in computer systems, scales and in measurement and control technology
NOTES
• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
₹ 57 / Meter Get Latest Price
| Size (Cross-sectional Area) | 4 sq mm |
| Conductor Material | Copper |
| Material | Copper |
| Insulation Type | FRLSH (FR Low Smoke Hal) |
| Size | 4 sq mm |
| Sheathing | Sheathed |
| Shape | Round |
| Voltage Rating | 1100 V |
| Number of Cores | 1 Core |
| Standard Coil Length | 100 m |
| Temperature Range | -20 - 70 degree c |
| Conductor Type | Flexible Stranded |
| Helukabel | 1000 |
| Colour | Yellow |
Minimum order quantity: 100 Meter
TECHNICAL DATA
TESTS
· flame-retardant acc. to BIS IS 10810-5: 1984 / IEC 60332-1-2
CABLE STRUCTURE
· annealed bare copper, finely stranded class 5 acc. to BIS IS 8130: 2013 / IEC 60228
· core insulation: FR-LSH PVC type D acc. to BIS IS 5831: 1984
PROPERTIES
· flame retardant
· low smoke
· low halogen
· the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
APPLICATION
Building wire for installation on wall surface or in concealed conduits. For lighting and power supply applications in residential buildings, commercial complexes and technological parks.
₹ 79 / Piece Get Latest Price
| Connector Type | Data Cable |
| Fast Charging Support | No |
| Brand | Helukabel |
| Cable Length | 100 m |
| Color | Grey |
| Cable Material | PVC |
Minimum order quantity: 1000 Piece
Cables for Industrial and Machinery Sectors
Data and Computer Cables
Data Cables
DATAFLAMM® grey 4 x 0.34 mm²Part no. 52330
colour code DIN 47100, without colour repetition, low capacitance
TECHNICAL DATA
Data cable Temperature range flexible +5°C to +70°C fixed -40°C to +70°C
Peak operating voltage 0.14 mm²: 350 V 0.25 - 0.75 mm²: 500 V (not for high power current installation purposes)
Test voltage core/core 0.14 mm²: 800 V 0.25 - 0.75 mm²: 1200 V
Mutual capacitance core/core at 800 Hz, approx. 70 pF/m
Minimum bending radius flexible 7.5x Outer-Ø fixed 4x Outer-Ø
CABLE STRUCTURE
• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
• Wire structure:
0.14 mm²: approx. 18 x 0.1 mm
0.25 mm²: approx. 14 x 0.15 mm
0.34 mm²: 7 x 0.25 mm
• Core insulation: PE acc. to DIN VDE 0819-103 / DIN EN 50290-2- 23 (compound type LD/MD)
• Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core
• x = without protective conductor
• Cores stranded in layers with optimal lay lengths
• Outer sheath: thermoplastic compound acc. to DIN VDE 0207-24 (compound type HM2)
• Sheath colour: grey (RAL 7005)
• Length marking: in metres
PROPERTIES
• halogen-free
• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
• PE-insulated cores ensure substantially lower capacity values than PVC-insulated cores
TESTS
• halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1
• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 / DIN EN 60754-2 / IEC 60754-2
• flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332- 1-2 / IEC 60332-1-2 (outer sheath)
• certifications and approvals:
EAC
APPLICATION
DATAFLAMM® halogen-free data cables are used as connection cables for signal, measurement and control technology, call systems and intercoms, clock systems, electronic weighing equipment and office machines. The cables can be laid on plaster and in dry, damp and wet rooms. Areas of application include telecommunication devices and information processing systems in public buildings, laboratories, department stores and other buildings where the release of halogens must be avoided in the event of fire. The halogen-free thermoplastic sheath does not emit corrosive or toxic gases.
NOTES
• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
₹ 116 / Meter Get Latest Price
| Cable Type | Cat 5e UTP |
| Cable Length | 500 |
| Conductor Material | Bare Copper |
| Number Of Pairs | 4 Pair |
| Shielding | UTP |
| Jacket Material | PVC |
| Color | Grey |
| Packaging Type | Roll |
| Flame Rating | FRLS |
Minimum order quantity: 500 Meter
Cables for Infrastructures and Buildings
Network Cables
LAN Cable Cat. 5e
HELUKAT® 200 CAT.5e SF/UTP FRNC FLEX
HELUKAT® 200 CAT.5e SF/UTP FRNC FLEX grey 4 x 2 x AWG 26 /7Part no. 81254
₹ 55 / Meter Get Latest Price
| Connector Type | Data Cable |
| Fast Charging Support | No |
| Brand | Data Cable |
| Cable Length | 500 m |
| Cable Material | PVC |
| Color | Grey |
Minimum order quantity: 1000 Meter
Cables for Industrial and Machinery Sectors
Data and Computer Cables
Data Cables
DATAFLAMM® grey 2 x 0.34 mm²Part no. 52328
colour code DIN 47100, without colour repetition, low capacitance
TECHNICAL DATA
Data cable
Temperature range flexible +5°C to +70°C fixed -40°C to +70°C
Peak operating voltage 0.14 mm²: 350 V 0.25 - 0.75 mm²: 500 V (not for high power current installation purposes)
Test voltage core/core 0.14 mm²: 800 V 0.25 - 0.75 mm²: 1200 V
Mutual capacitance core/core at 800 Hz, approx. 70 pF/m
Minimum bending radius flexible 7.5x Outer-Ø fixed 4x Outer-Ø
CABLE STRUCTURE
• Copper wire bare, 0.5 - 0.75 mm²: finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
• Wire structure: 0.14 mm²: approx. 18 x 0.1 mm 0.25 mm²: approx. 14 x 0.15 mm 0.34 mm²: 7 x 0.25 mm
• Core insulation: PE acc. to DIN VDE 0819-103 / DIN EN 50290-2- 23 (compound type LD/MD) • Core identification in alignment with DIN 47100, colour coded without colour repetition from the 45th core
• x = without protective conductor
• Cores stranded in layers with optimal lay lengths
• Outer sheath: thermoplastic compound acc. to DIN VDE 0207-24 (compound type HM2)
• Sheath colour: grey (RAL 7005)
• Length marking: in metres
PROPERTIES
• halogen-free
• the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
• PE-insulated cores ensure substantially lower capacity values than PVC-insulated cores
TESTS
• halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1
• corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 / DIN EN 60754-2 / IEC 60754-2
• flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332- 1-2 / IEC 60332-1-2 (outer sheath)
• certifications and approvals: EAC
APPLICATION
DATAFLAMM® halogen-free data cables are used as connection cables for signal, measurement and control technology, call systems and intercoms, clock systems, electronic weighing equipment and office machines. The cables can be laid on plaster and in dry, damp and wet rooms. Areas of application include telecommunication devices and information processing systems in public buildings, laboratories, department stores and other buildings where the release of halogens must be avoided in the event of fire. The halogen-free thermoplastic sheath does not emit corrosive or toxic gases.
NOTES
• the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
₹ 35 / Meter Get Latest Price
| Size (Cross-sectional Area) | 2.5 sq mm |
| Conductor Material | Copper |
| Insulation Type | FRLSH (FR Low Smoke Hal) |
| Flexibility | Stranded |
| Sheathing | Unsheathed |
| Number of Cores | 1 Core |
| Standard Coil Length | 100 m |
| Colour | Yellow |
Minimum order quantity: 100 Meter
Sales Team
Allelectro Inconnects Private Limited
Gf-10, Shoppers Square, Sector-14
Ghaziabad - 201002, Uttar Pradesh, India